Eaton Metered Input Rack Power Distribution Unit, Form Factor: 0u, L6-20p, C20 IEngineered for efficiency, reliability, and precise energy governance, the Eaton metered input rack power distribution unit (PDU) delivers essential power distribution with real time metering for data centers, server rooms, and high density IT environments. Its compact 0U form factor fits snugly into standard 19 inch racks, freeing valuable front panel space for equipment while providing robust protection and visibility over your power usage. With a
Engineered for efficiency, reliability, and precise energy governance, the Eaton metered input rack power distribution unit (PDU) delivers essential power distribution with real-time metering for data centers, server rooms, and high-density IT environments. Its compact 0U form factor fits snugly into standard 19-inch racks, freeing valuable front panel space for equipment while providing robust protection and visibility over your power usage. With a single-phase configuration, 100–240V compatibility, and a 3.84 kW maximum load, this PDU is designed to support a wide range of IT assets and networking gear, from blade servers to multi-rack middleware nodes. The combination of versatile outlets, a long 10-foot cord, and a reliable L6-20P input makes it a flexible solution for installations where space, efficiency, and monitoring matter most. Whether you’re aiming to optimize energy costs, track power trends, or simply simplify cabling in a crowded data center, this Eaton PDU is purpose-built to meet those demands while maintaining uptime and operational clarity.
- Metered power distribution with real-time monitoring to help you track voltage, current, and power, enabling proactive capacity planning and energy efficiency across IT workloads.
- Flexible input and outlets: 100-240V input range with a 10 ft cord and an L6-20P plug; outputs include (18) C13 outlets and (2) C19 outlets to accommodate a mix of servers, switches, storage devices, and other rack-mount gear.
- Compact 0U form factor for space-saving deployment in standard 19-inch racks, providing clean cabling and front-access power distribution without occupying front-panel rack space.
- High-capacity single-phase performance up to 3.84 kW and 16A capacity, enabling reliable power delivery for dense rack environments while maintaining safe headroom for peak workloads.
- Durable, enterprise-grade construction designed for continuous operation in data centers and network labs, with trusted Eaton reliability and built-in protection features to help safeguard critical equipment.
Technical Details of Eaton Metered Input Rack Power Distribution Unit
- Form Factor: 0U
- Input Connector: L6-20P
- Input Voltage Range: 100–240V
- Input Current: 16A
- Maximum Load: 3.84 kW
- Cord Length: 10 ft
- Phase: Single-phase
- Output Connectors: (18) C13 outlets, (2) C19 outlets
- Input/Output Configuration: Metered input with multiple receptacles for mixed device support
how to install Eaton Metered Input Rack Power Distribution Unit
- Power down and unplug equipment that will be connected to the PDU; plan cable routing to maintain clean, organized wiring in the rack.
- Mount the PDU into a 19" rack using compatible mounting rails or hardware; ensure the unit sits securely and that all outlets remain accessible for front-bar access.
- Connect the 10-foot power cord to a suitable 100–240V power source using the L6-20P inlet; verify that the outlet circuit can handle up to 16A continuously without tripping for sustained peak loads.
- Distribute devices across the (18) C13 and (2) C19 outlets to balance current across outlets and prevent single-outlet overload; group critical devices on dedicated circuits where possible.
- Power on the PDU and connected equipment; monitor energy usage through the metering interface to validate load distribution and identify opportunities for optimization in real time.
Frequently asked questions
-
Q: What is the form factor and where can I install it?
A: The PDU has a 0U form factor designed for standard 19-inch racks, making it ideal for dense data centers, server rooms, and network cabinets where space is at a premium.
-
Q: What outlets are available on this unit?
A: It provides (18) C13 outlets and (2) C19 outlets, suitable for a mix of servers, switches, storage devices, and other rack-mount equipment.
-
Q: What is the input specification?
A: The PDU accepts 100–240V at up to 16A with an L6-20P input connector, and it includes a 10-foot cord for flexible power placement in the rack enclosure.
-
Q: How much load can it support?
A: The maximum load is 3.84 kW, providing ample headroom for typical mixed-rack deployments while allowing for efficient energy management.
-
Q: Does it offer metered power?
A: Yes. The unit provides metered input power which enables real-time monitoring of voltage and current to aid with capacity planning and energy optimization.
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy